AHU maintenance, servicing and repairs

Air Handling Unit Services in London

Air handling units move, filter and condition the air that whole floors and buildings breathe. We maintain, service and repair commercial AHUs across London.

  • London & Greater London
  • 24/7 contact line
  • Commercial buildings only
Rooftop HVAC unit with large axial fans and insulated ductwork being checked by an engineer
Illustrative image

In short

Air handling unit services cover the planned maintenance, servicing and repair of the AHUs that supply and extract conditioned air in commercial buildings. Engineers check and change filters, inspect fans, belts and motors, clean coils and drain trays, test dampers, heat recovery and frost protection, and verify controls, so the unit delivers the right airflow efficiently and hygienically.

What AHU services involve

AHU section What we check
Filters Condition, fit, seals and pressure drop
Fans and motors Bearings, belts and pulleys, alignment, current draw, EC fan operation
Heating and cooling coils Cleanliness, fin damage, leaks, valve operation
Drain trays and traps Blockages, standing water, corrosion, trap seals
Dampers Movement, linkages, actuators, seals
Heat recovery Thermal wheels, plate heat exchangers, run-around coils
Humidifiers Condition, water treatment and hygiene, where fitted
Controls Sensors, frost protection, fan speed control, interlocks

When AHU work is needed

  • planned maintenance visits under your schedule
  • rooms feel stuffy, draughty, too hot or too cold
  • the AHU is noisy or vibrating
  • filter alarms or fan failure alarms on the BMS
  • energy use has risen or air volumes no longer match design

Equipment covered

Packaged and modular AHUs, roof-mounted and plant-room units, supply-only and supply-and-extract units, units with heat recovery, and the associated fans, dampers, coils and controls.

Our process

  1. Share the number, type and location of AHUs, plus any alarms or complaints.
  2. We survey or attend to service, following the site’s isolation and permit procedures.
  3. Each unit is inspected, cleaned, tested and recorded.
  4. Defects are reported with recommended remedies for your approval.

Typical applications

Office floors served by central AHUs, hotel public areas and kitchens, retail sales floors, education buildings and healthcare premises.

Maintenance considerations

  • Track filter pressure drop rather than changing filters only by date.
  • Keep drain trays draining freely; standing water is a hygiene risk.
  • Check belt tension and alignment regularly to avoid premature wear.
  • Confirm that frost protection works before winter.

Compliance and safety

Isolate before opening. AHU fans can start automatically under BMS control. Safe isolation and lock-off are essential before any access panel is opened.

Employers must provide sufficient fresh air under the Workplace Regulations. Where an AHU has humidifiers or wet sections, include it in the legionella risk assessment.

Coverage across London

We take AHU enquiries for commercial buildings across London and Greater London. See areas we cover.

Air Handling Units: frequently asked questions

How often should AHU filters be changed?

It depends on the filter grade, the air quality outside, the hours the unit runs and the pressure drop across the filter. Many sites inspect filters monthly or quarterly and change them when the pressure drop reaches the manufacturer's recommended final value.

Why is our air handling unit noisy?

Common causes are worn or slack belts, failing bearings, an unbalanced fan, loose panels, or dampers and ductwork vibrating. Noise often gets worse before a failure, so it should be investigated promptly.

Do AHUs need legionella checks?

Where an AHU has a humidifier, evaporative cooling section or standing water in its drain trays, the legionella risk should be included in the building's risk assessment and controlled as HSE's ACOP L8 describes.

Can you upgrade an old AHU's fans to EC fans?

Fan upgrades to EC (electronically commutated) motors are a common way to cut energy use and improve control. Suitability depends on the unit's casing, airflow requirements and controls, so a survey comes first.

What is included in an AHU service?

Typically filters, fans, belts and pulleys, bearings, motors, coils, drain trays and traps, dampers and actuators, heat recovery devices, frost protection, humidifiers where fitted, and controls and sensors.

UK guidance and references

Primary and industry sources relevant to this subject. Always check the current edition and how it applies to your building.

Enquiry form

Request air handling units support

Tell us about the building, the equipment and what you need. Your enquiry goes straight to the Commercial HVACS team at info@flairfacilities.co.uk.

Urgent fault or loss of cooling, heating or ventilation? Call our 24/7 contact line rather than using the form: 020 7998 9005. Attendance depends on location, engineer availability and site access.

  • Fields marked with an asterisk are required
  • No marketing sign-up: we use your details only to respond
  • See our privacy policy
A full UK postcode, for example EC1V 2NX
The building, the system and what you would like us to do (at least 20 characters).
Add equipment and site details (optional, helps us respond accurately)
Any fault codes, alarms, noises, leaks or symptoms you have noticed.

By sending this form you agree we may contact you about this enquiry. We do not add you to marketing lists.