Supply, extract and heat recovery systems

Commercial Ventilation Services in London

Maintenance, repair and installation of the ventilation systems that bring fresh air into commercial buildings and remove stale air, moisture and odours.

  • London & Greater London
  • 24/7 contact line
  • Commercial buildings only
Rooftop HVAC unit with large axial fans and insulated ductwork being checked by an engineer
Illustrative image

In short

Commercial ventilation services cover the maintenance, repair and installation of systems that supply fresh air and extract stale air in commercial buildings. That includes supply and extract fans, heat recovery units, ductwork, grilles, dampers and controls. Engineers check airflow, fans, belts, filters and controls so occupied spaces receive adequate fresh air efficiently, as workplace regulations require.

What ventilation services involve

  • fan inspection, belt and bearing checks, and motor checks
  • filter checks and replacement
  • heat recovery unit inspection and cleaning
  • damper and actuator operation
  • airflow measurement at key terminals where required
  • controls checks, including time schedules, speed control and CO2 sensors

When ventilation work is needed

  • occupants complain of stuffy, stale or humid air
  • fans are noisy, vibrating or have stopped
  • spaces have been re-planned or occupancy has increased
  • energy use suggests fans run longer than needed
  • you are refurbishing and need to meet current ventilation requirements

Equipment covered

Equipment Typical work
Supply and extract fans Maintenance, repair, replacement, EC motor upgrades
Heat recovery units Filters, heat exchangers, bypass dampers, controls
Toilet and general extract Fans, controls, run-on timers
Ductwork, grilles and dampers Inspection, access, damper operation
Ventilation controls CO2 and occupancy sensors, schedules, BMS points

Our process

  1. Describe the system and the problem, or ask us to survey.
  2. We inspect, test and record the system’s condition and operation.
  3. Repairs are carried out or quoted for approval.
  4. You receive a report with any recommendations.

Typical applications

Offices, meeting rooms, hotel bedrooms and corridors, retail units, warehouses, classrooms and healthcare premises.

Maintenance considerations

Ventilation systems are easy to forget because they are mostly hidden. Keep a schedule for fans, filters and heat recovery units, and make sure time schedules match how the building is actually used.

Compliance and safety

Regulation 6 of the Workplace (Health, Safety and Welfare) Regulations 1992 requires effective and suitable ventilation in enclosed workplaces. New or altered systems should meet Approved Document F.

Moving parts and electrical supplies. Fans can start automatically. Safe isolation is required before any access panel is opened.

Coverage across London

We take ventilation enquiries across London and Greater London. See areas we cover.

Commercial Ventilation: frequently asked questions

How do we know if our ventilation is adequate?

Signs of poor ventilation include stuffiness, condensation, lingering odours and complaints of drowsiness. CO2 monitoring is a practical indicator of whether occupied spaces are receiving enough fresh air. HSE gives guidance on using CO2 monitors in the workplace.

What is demand-controlled ventilation?

Demand-controlled ventilation adjusts fresh air rates to occupancy, typically using CO2 or occupancy sensors. It can maintain air quality while reducing fan and heating energy when spaces are lightly used.

Do you clean kitchen extract ductwork?

Specialist kitchen extract grease cleaning is carried out to its own industry standard and is not covered on this page. We can maintain and repair the fans and controls serving general extract systems.

Why is our extract fan noisy?

Typical causes are worn bearings, a slack or damaged belt, an unbalanced impeller, debris in the fan or loose mountings. Noise should be investigated before the fan fails.

What is heat recovery ventilation?

Heat recovery units transfer heat between extract and supply air, reducing the energy needed to heat or cool incoming fresh air. They need regular filter changes and checks on the heat exchanger and bypass dampers.

UK guidance and references

Primary and industry sources relevant to this subject. Always check the current edition and how it applies to your building.

Enquiry form

Request commercial ventilation support

Tell us about the building, the equipment and what you need. Your enquiry goes straight to the Commercial HVACS team at info@flairfacilities.co.uk.

Urgent fault or loss of cooling, heating or ventilation? Call our 24/7 contact line rather than using the form: 020 7998 9005. Attendance depends on location, engineer availability and site access.

  • Fields marked with an asterisk are required
  • No marketing sign-up: we use your details only to respond
  • See our privacy policy
A full UK postcode, for example EC1V 2NX
The building, the system and what you would like us to do (at least 20 characters).
Add equipment and site details (optional, helps us respond accurately)
Any fault codes, alarms, noises, leaks or symptoms you have noticed.

By sending this form you agree we may contact you about this enquiry. We do not add you to marketing lists.