Commercial Chiller Maintenance: What Building Managers Should Monitor

Commercial HVACS technical team, Flair Facilities Ltd Updated 3 min read

Quick answer

Building managers should monitor chilled water flow and return temperatures, the difference between them, chiller alarms and trips, compressor starts and run hours, and condenser condition. Rising approach temperatures, frequent starts and recurring alarms usually show a developing fault. Planned chiller maintenance adds refrigerant leak checks, electrical and compressor checks, water treatment and condenser cleaning.

Why chiller monitoring matters

In a chilled water building, one or two chillers supply cooling to every air handling unit and fan coil. When a chiller fails, the whole building feels it. Chiller faults rarely appear without warning: they show up first as changes in temperatures, pressures, alarms and run patterns. If someone is watching those trends, problems can be fixed in planned time rather than during a heatwave.

Readings building managers can watch

You do not need to be a refrigeration engineer to spot a developing problem. Most chiller controllers and BMS systems show these values:

Reading What normal looks like What to watch for
Chilled water flow temperature Close to setpoint, stable Drifting above setpoint under load
Chilled water return temperature Rises and falls with building load Very close to flow temperature for long periods
Flow-to-return difference (delta T) Near the design value Persistently low: often a sign of overpumping or control valve problems
Compressor starts per hour Within manufacturer limits Frequent short cycling
Run hours Even across chillers and compressors where duty rotation is used One machine doing all the work
Alarms and trip history Rare, explained events Repeat alarms of the same type
Condenser condition (air-cooled) Clean coils, fans all running, clear airflow Debris, failed fans, hot air recirculating

A low delta T is one of the most common chilled water problems. When return water comes back barely warmer than flow water, chillers run more machines than needed, pumps use more energy, and spaces at the end of the system can still be warm.

What engineers check

A planned chiller maintenance visit typically covers:

  • refrigerant pressures, superheat and subcooling compared with expected values
  • evaporator and condenser approach temperatures, which rise as heat exchangers foul
  • compressor oil level, oil condition and, where specified, oil analysis
  • electrical connections, contactors, starters and drives, including thermal imaging where specified
  • condenser coil cleaning and fan operation on air-cooled machines
  • flow switches, safety devices and interlocks
  • controls, setpoints, sequencing and BMS integration
  • statutory F-gas leak checks at the interval set by the refrigerant charge
  • water treatment and strainers on the chilled water side

Air-cooled condensers

Many chillers serving London commercial buildings are air-cooled and sit on roofs. Their condenser coils collect dust, pollen, leaves and pigeon debris. Dirty coils raise condensing pressure, increase energy use and cause high-pressure trips on the hottest afternoons, which is exactly when cooling is needed most. Pre-summer coil cleaning and a check that no plant, screens or stored items restrict airflow make a noticeable difference.

Water treatment

The chilled water circuit needs treating to control corrosion, scale and microbiological growth. Poor water quality fouls heat exchangers and control valves and can cause strainer blockages and pump failures. Regular sampling and dosing should be part of the maintenance arrangement for the whole circuit, not just the chiller.

Water-cooled chillers that reject heat through cooling towers or evaporative condensers are a legionella risk. These must be notified to the local authority and managed under HSE’s ACOP L8.

Compliance points

  • F gas: chillers often hold large refrigerant charges, which puts many into the 6-monthly leak check band or the band where automatic leak detection is mandatory. See our F-gas leak check guide.
  • Pressure systems: refrigeration systems can fall within the Pressure Systems Safety Regulations 2000. Whether a written scheme of examination is required depends on the system. Confirm with a competent person or your insurer.
  • TM44: chilled water systems are air conditioning systems under the energy performance regulations and need a TM44 inspection at least every five years.

Using trend data

If your BMS logs chiller data, a monthly look at a few trends will catch most developing problems early:

  1. Chilled water flow temperature against setpoint.
  2. Delta T across the plant.
  3. Compressor starts and run hours.
  4. Alarm counts by type.

Changes in these are worth raising with your maintenance contractor before they become breakdowns. See HVAC controls and BMS.

When to call for help

Call an engineer for repeated trips, a chiller that will not restart, loss of cooling to critical areas, refrigerant alarms or visible oil and refrigerant leaks. For an urgent loss of cooling, use our 24/7 contact line on 020 7998 9005. For planned work, see chiller services.

Frequently asked questions

What chiller readings matter most?

For non-engineers, the most useful are chilled water flow and return temperatures, the temperature difference between them, the active alarm list, and compressor starts and run hours. Engineers will also look at refrigerant pressures, superheat, subcooling and approach temperatures.

Does the Pressure Systems Safety Regulations apply to chillers?

Refrigeration systems can fall within the Pressure Systems Safety Regulations 2000, and some need a written scheme of examination depending on their size. Check with a competent person or your engineering insurer, and see HSE's pressure systems guidance.

Why does our chiller trip on hot days?

High-pressure trips on hot days are often caused by dirty condenser coils, failed condenser fans, poor airflow around the chiller or recirculation of hot discharge air. Overcharged or contaminated refrigerant can also contribute.

How often should a chiller be serviced?

Many commercial chillers receive quarterly planned visits with a more detailed annual inspection, plus statutory F-gas leak checks at the interval set by their refrigerant charge. Manufacturer guidance and schedules such as SFG20 are used to set the detail.

Do air-cooled chillers need legionella control?

Air-cooled chillers do not have the cooling tower risk. Water-cooled chillers that reject heat through cooling towers or evaporative condensers do, and those must be notified to the local authority and managed under HSE's ACOP L8.

UK guidance and references

Primary and industry sources relevant to this subject. Always check the current edition and how it applies to your building.

This guide is general information for commercial building operators. It does not replace an assessment of your building by a competent engineer. If there is an immediate risk to people, contact the emergency services first.