Quick answer
A commercial HVAC maintenance checklist should cover three things. First, records: an accurate asset register, maintenance schedule and F-gas logs. Second, compliance: F-gas leak checks, TM44 inspections, legionella controls and ventilation duties. Third, equipment tasks for each asset: filters, coils, drains, fans, belts, refrigerant checks and controls. Facilities managers should check all three regularly, not just that visits happen.
How to use this checklist
This is a management checklist, not a set of engineering instructions. Use it to check that your HVAC maintenance arrangements are complete and working. Your contractor should hold the detailed task lists for each asset.
1. Records and documentation
- An asset register listing every HVAC asset with location, make, model, serial number and age
- A maintenance schedule setting tasks and frequencies for each asset type
- Visit records for the last 12 months, showing tasks done and readings taken
- An open defects list, with dates raised and target dates for resolution
- Operation and maintenance manuals and as-installed drawings, where available
- Contact and out-of-hours arrangements for HVAC faults
2. Compliance
- F-gas register: refrigerant type and charge for each system, with CO2-equivalent calculated
- F-gas leak checks carried out at the required intervals, with records kept
- TM44 inspection reports for air conditioning systems over 12 kW, less than five years old
- Legionella risk assessment covering humidifiers, evaporative cooling and other relevant HVAC water systems
- Evidence that occupied spaces receive adequate ventilation, for example CO2 monitoring
- Pressure system written schemes of examination, where applicable
3. Equipment tasks to expect
| Asset | Tasks your schedule should include |
|---|---|
| Air handling units | Filters, fans and belts, bearings, coils, drain trays, dampers, frost protection, heat recovery |
| Fan coil units | Filters, condensate drains and pumps, valves and actuators, fans, controllers |
| Air conditioning | Indoor and outdoor coils, drains, refrigerant checks, controls |
| Chillers | Operating readings, alarm history, condensers, flow checks |
| Heat pumps | Coils, defrost, flow temperatures, refrigerant checks |
| Ventilation | Fans, belts, filters, dampers, controls |
| Controls | Sensor checks, setpoints, schedules, interlocks |
4. Seasonal checks
- Before summer: air conditioning and chiller condenser cleaning, drain checks, cooling performance checks
- Before winter: heating and heat pump checks, frost protection, defrost operation
- After occupancy changes: time schedules and setpoints reviewed
5. Performance and review
- Recurring faults reviewed to find root causes
- Energy use reviewed against occupancy
- Replacement planning for assets near the end of their life
- Schedule reviewed annually and updated for new or removed assets
Red flags
Act on these promptly. Missing F-gas records, no legionella risk assessment for humidified AHUs, repeated water leaks from ceiling units, and defects left open for months all point to maintenance that is not working.
Next steps
If your checklist shows gaps, an HVAC system assessment will establish the baseline. A structured maintenance contract then keeps everything on track.
Frequently asked questions
Should facilities staff carry out any HVAC tasks themselves?
Simple, non-invasive checks are useful, such as noting alarms, unusual noise, leaks or blocked grilles. Anything involving opening equipment, electrical isolation, refrigerant or work at height should be left to competent engineers.
How do I know my contractor is doing what the schedule says?
Ask for visit records that list each asset, the tasks done and readings taken. Spot-check filters and drains occasionally, and review defect reports to make sure issues are being closed out.
UK guidance and references
Primary and industry sources relevant to this subject. Always check the current edition and how it applies to your building.
- SFG20 standard maintenance specification BESA / SFG20
- Workplace (Health, Safety and Welfare) Regulations 1992 legislation.gov.uk
- F gas in refrigeration and air conditioning GOV.UK
- Legionnaires' disease (ACOP L8) Health and Safety Executive
This guide is general information for commercial building operators. It does not replace an assessment of your building by a competent engineer. If there is an immediate risk to people, contact the emergency services first.